1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6032-6035, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947221

RESUMO

We present proof of concept experiment of a sensing method to detect skin hydration using a low-cost bio-impedance sensor. The sensing system is validated by testing its current output over frequencies between 1 kHz and 50 kHz and comparing measured values of impedance. A series of experiments with salt-water mixtures as well as a gelatin-based phantom were carried out to test the sensor's ability to detect small changes in impedance due to changes in water content. We also compared impedance measurements from the phantom to human skin to confirm that the manufactured phantoms can mimic skin properties successfully. Our experimental results show that the sensor can detect small changes in salt concentration and can capture the correlation between the impedance and skin hydration in a reliable manner.


Assuntos
Pele , Impedância Elétrica , Estudos de Viabilidade , Humanos , Imagens de Fantasmas
2.
Sci Rep ; 7(1): 6855, 2017 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-28761121

RESUMO

We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l.


Assuntos
Glicemia/análise , Rádio/instrumentação , Adulto , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Teste de Tolerância a Glucose/instrumentação , Teste de Tolerância a Glucose/métodos , Humanos , Masculino , Pessoa de Meia-Idade